Capture serial port data wireshark8/30/2023 Protocol identifier : always 0 for Modbus TCP.Transaction identifier : to synchronize communication between devices.This post is based on the same video, together with some of my findings when I did the labs. I based my previous post with an Intro to PLCs, ICS and SCADA on a Black Hat 2014 presentation by Arnaud Soullié in a Industrial Control Systems : Pentesting PLCs 101. In TCP we often refer to the Master as the Client and to the Slave as the Server. In the serial world, the devices have to been connected in a daisy-chain manner, not in a star topology. You can have only one Master on a “Modbus” network and maximum 247 slaves, each with a unique slave ID. Modbus RTU (uses binary encoding and a CRC error check).Modbus TCP (no checksum as lower network layers should include a checksum).For serial communication, Modbus ASCII and Modbus RTU are incompatible (meaning you have to use one or the other but not both on a network).Įvery Modbus variant has to choose a frame format: Other versions of Modbus (used in serial communication) are for example Modbus RTU and Modbus ASCII. Modbus is a clear text protocol with no authentication.Īlthough it was initially developed for serial communication it is now often used over TCP. This means the Master has the pull the information from a Slave at regular times. It is the most widespread used protocol within ICS. Modbus is a serial communication protocol.